APC SRTG6KXLI uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA 6000 W 3 AC outlet(s)
APC SRTG6KXLI uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA 6000 W 3 AC outlet(s)
4,354.05€
Ex Tax: 3,598.39€
- Stock: 1
- Model: SRTG6KXLI
- ISBN: 0731304411826
- MPN: SRTG6KXLI
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
Cold-start capable
Provides temporary battery power when the utility power is out.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Input Power Factor Correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
SmartSlot
Customize UPS capabilities with management cards.
Network manageable
Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
Serial connectivity
Provides management of the UPS via a serial port.
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
LED status indicators
Quickly understand unit and power status with visual indicators.
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
Cold-start capable
Provides temporary battery power when the utility power is out.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Input Power Factor Correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
SmartSlot
Customize UPS capabilities with management cards.
Network manageable
Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
Serial connectivity
Provides management of the UPS via a serial port.
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
LED status indicators
Quickly understand unit and power status with visual indicators.
Battery | |
Battery voltage | 96 V |
Battery technology | Sealed Lead Acid (VRLA) |
Battery life (max) | 5 year(s) |
Battery recharge time | 4 h |
Hot-swap battery | Yes |
Automatic battery test | Yes |
Cold start | Yes |
Features | |
UPS topology | Double-conversion (Online) |
Output power capacity | 6 kVA |
Output power | 6000 W |
Waveform | Sine |
Input operation voltage (min) | 100 V |
Input operation voltage (max) | 285 V |
Input frequency | 40/70 Hz |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Output frequency | 50/60 Hz |
Emergency Power Off (EPO) | Yes |
Surge energy rating | 600 J |
Crest factor | 3:1 |
Output voltage Total Harmonic Distortion (THD) | 2% |
ECO mode | Yes |
Noise level | 55 dB |
Audible alarm(s) | Yes |
Audible alarm modes | Alarm when on battery, Low battery alarm, Overload alarm |
Operational conditions | |
Operating relative humidity (H-H) | 0 - 95% |
Storage temperature (T-T) | -15 - 45 °C |
Operating temperature (T-T) | 0 - 40 °C |
Storage relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 2011 m |
Non-operating altitude | 0 - 15240 m |
Ports & interfaces | |
Emergency Power Off (EPO) connector | Yes |
AC outlet types | C13 coupler, C19 coupler |
AC outlets quantity | 3 AC outlet(s) |
USB port | Yes |
Serial interface | Yes |
Ethernet LAN (RJ-45) ports | 1 |
SmartSlot | Yes |
Weight & dimensions | |
Width | 440 mm |
Depth | 620 mm |
Height | 178 mm |
Weight | 51.9 kg |
Package width | 590 mm |
Package depth | 790 mm |
Package height | 275 mm |
Package weight | 59 kg |
Design | |
International Protection (IP) code | IP20 |
Form factor | Compact |
Product colour | Black |
Display type | LCD |
LED indicators | Yes |
Certification | CE, EN/IEC 62040-1 |